TSV101
Teracom AC voltage detector TSV101, 85/170 V AC, DIN rail, IP30
| Manufacturer: | Teracom |
|---|---|
| Manufacturer no.: | TSV101 |
| Product no.: | S-064-156874 |
Available, Delivery time: 3 weeks
Product information
Description
Technical data
| Weight: | 0.1 kg |
|---|---|
| Country of origin: | Bulgaria |
Downloads
You might also be interested in
More information
The Teracom TSV101 is an electronic AC voltage detector designed to indicate the presence or absence of mains voltage. It features a galvanically isolated open-collector output and is designed for DIN rail mounting.
Voltage detection
The TSV101 supports two detection ranges, selectable using an internal jumper. Detection is supported for AC voltages up to 250 V AC.
- Detection range with jumper open: 85 to 250 V AC.
- Detection range with jumper closed: 170 to 250 V AC.
- Factory default: 170 V AC, jumper closed.
- Working voltage range according to manufacturer: 0 to 250 V AC.
- AC networks: Suitable for 115 V and 230 V AC systems.
Galvanic isolation and output
Galvanic isolation between the monitored AC voltage and the digital output is provided by an optocoupler. The output uses an open-collector configuration.
The detector can be connected to digital inputs of Teracom TCW1xx, TCW2xx and TCG1xx controller families, as well as corresponding inputs of third-party controllers. The digital input must operate in dry-contact mode.
The device is powered exclusively by the monitored AC voltage. No additional power supply is required.
Construction and operating conditions
- Electronic circuitry without mechanical or electromechanical switching elements.
- Galvanically isolated open-collector output.
- Two jumper-selectable detection thresholds.
- Low temperature drift according to the manufacturer.
- Ingress protection: IP30.
- Dimensions: 85 × 35.1 × 23.5 mm.
- Operating temperature: 0 to +40 °C.
- Permissible relative humidity: 5 to 85% RH, non-condensing.
Mounting and connection
The TSV101 is designed for installation on a DIN rail. It provides terminals for the monitored AC voltage (L and N) and the digital output (OUT and GND).
The detection threshold is configured using a jumper located on the internal printed circuit board.
Safety notice: Dangerous mains voltage is present inside the enclosure. The detector must be disconnected from the AC power line before opening the enclosure or changing the jumper setting.
Applications
- Detection and notification of mains voltage failures.
- Input voltage monitoring for uninterruptible power supplies (UPS).
- Voltage monitoring of power supplies and electrical lines.
- Integration into industrial automation and process control systems.
- Integration into load management systems during battery operation.
Warranty: 3 years for business customers.